Film Cooling Towers Limited, otherwise Film Cooling Towers (1925) Limited, was a British limited liability company, originally established in 1914, to design and construct cooling towers for the chemical and electricity industries. It was operational until 1970.

Background Film Cooling Towers Limited was established in 1914 and Incorporated in 1915. It manufactured cooling towers, cooling frames and air filters. It had capital of £6,000 of which £5,352 was issued. In 1922 its directors were Edward Hunter Low, W. W. White, L. Clemow and P. Eric Jeffcock. It employed 20 people and its offices were at 124 Chancery Lane, London, WC2.  

The name ‘film’ refers to the falling film of hot water that the company’s cooling towers internal structures produced, as opposed to falling droplets or spray.  

The company went into liquidation in 1925. Its assets were acquired by Film Cooling Towers (1925) Limited.The Bioscope, London, 2 Apr 1925

Film Cooling Towers (1925) Limited This company was founded by Karl Wladimir Branczik (1878 – 1953) and was registered on 28 March 1925. It acquired the assets of the 1914 company. Its first Directors were A.V. de la Salle and H. G. Geves. In 1958 the Directors were Isabel M. Branczik and E. A. Howe. Its works and registered office was at Lionel Road, Kew Bridge, Brentford, Middlesex. Its authorized capital was 6,000 ordinary shares of £1 each, with £5,250 issued.  

On 22 August 1938 a world-wide patent (GB518373) was granted to K.W. Branczik on improvements in or relating to cooling towers. Specifically it relates to a series of cooling laths arranged in zig-zag fashion, so as to baffle the entering air and to cause the water to fall into the pond in sheets extending towards the centre of the tower.

The company designed and constructed timber and reinforced concrete cooling towers and spray coolers for the chemical and electricity industries. Typical of its portfolio was a commission for the chemical industry:

Design and construct for BP Chemicals at its Baglan Bay chemicals plant, two natural draught hyperbolic cooling towers. Dimensions: height 296 ft., ring beam diameter 244 ft.; throat diameter 124 ft.; top diameter 131 ft. Cooling Towers, Biggleswade Chronicle, 19 September 1969

Electricity supply industry For the electricity supply industry the company built wooden and reinforced concrete, natural and induced draft, cooling towers. +Cooling towers constructed by Film Cooling Towers for the UK electricity industry.Power station Cooling tower: number, type, capacity Construction year Grimsby 3 × wood, 3 × concrete, total 2.47 mgph Film and other manufactures 1924-39 Bristol 2 × wood 0.9 mgph 1928 Watford 2 × 0.25 mgph  Before 1950 Upper Boat1 RC 2.25 mgph1924-9Brimsdown A2 = 2 mgph1938Brimsdown B5 = 6.6 mgph1928Llynfi1 RC 2.5 mgph1943Huncoat 2 × 3 mgph  1947-55 Rugeley 4 × 3.6 mgph RC  1958-61 Thorpe Marsh 4 × RC  1959-63  Ferrybridge C 8 × RC, 115 m high 1961-67 Drakelow C 6 × RC 1961 Richborough 3 × RC 1963 Ironbridge B 4 × RC  1963-68 Cottam 8 × RC, each 6.75 mgph, 114 m high 1964-70 Didcot 6 × 11.4 m3/s, RC 114 m high 91 m diam.  1965-70 Key: mgph – million gallons per hour; RC – reinforced concrete.

When successfully tendering for the £1.5 million contract to design and build the four cooling towers for Ironbridge power station, the company operated as Film Cooling Towers (Concrete) Limited.Ironbridge power station, Wolverhampton Express and Star, 9 June 1964 In November 1965 three of the cooling towers at Ferrybridge power station built by Film Cooling Towers (Concrete) Limited collapsed during a gale. Gales demolish three new cooling towers, The Guardian,  Nov 2, 1965 Film Cooling Towers (Concrete) Limited was a 50/50 joint venture between Film Cooling Towers (1925) Limited and J L Kier and Co.

In 1970 the company was taken over by Meyer International Group as an outlet for its wooden products.

See also List of cooling towers at UK power stations

References