A gas detector is a device that detects the presence of gases in a volume of space, often as part of a safety system. A gas detector can sound an alarm to operators in the area where the leak is occurring, giving them the opportunity to leave. This type of device is important because there are many gases that can be harmful to organic life, such as humans or animals.
Gas detectors can be used to detect combustible, flammable and toxic gases, and oxygen depletion. This type of device is used widely in industry and can be found in locations, such as on oil rigs, to monitor manufacturing processes and emerging technologies such as photovoltaic. They may be used in firefighting.
Gas leak detection is the process of identifying potentially hazardous gas leaks by sensors. Additionally a visual identification can be done using a thermal camera These sensors usually employ an audible alarm to alert people when a dangerous gas has been detected. Exposure to toxic gases can also occur in operations such as painting, fumigation, fuel filling, construction, excavation of contaminated soils, landfill operations, entering confined spaces, etc. Common sensors include combustible gas sensors, photoionization detectors, infrared point sensors, ultrasonic sensors, electrochemical gas sensors, and metal–oxide–semiconductor (MOS) sensors. More recently, infrared imaging sensors have come into use. All of these sensors are used for a wide range of applications and can be found in industrial plants, refineries, pharmaceutical manufacturing, fumigation facilities, paper pulp mills, aircraft and shipbuilding facilities, hazmat operations, waste-water treatment facilities, vehicles, indoor air quality testing and homes.
History Gas leak detection methods became a concern after the effects of harmful gases on human health were discovered. Before modern electronic sensors, early detection methods relied on less precise detectors. Through the 19th and early 20th centuries, coal miners would bring canaries down to the tunnels with them as an early detection system against life-threatening gases such as carbon dioxide, carbon monoxide and methane. The canary, normally a very songful bird, would stop singing and eventually die if not removed from these gases, signaling the miners to exit the mine quickly.
The first gas detector in the industrial age was the flame safety lamp (or Davy lamp) was invented by Sir Humphry Davy (of England) in 1815 to detect the presence of methane (firedamp) in underground coal mines. The flame safety lamp consisted of an oil flame adjusted to specific height in fresh air. To prevent ignition with these lamps the flame was contained within a glass sleeve with a mesh flame arrestor. The flames height varied depending on the presence of methane (higher) or the lack of oxygen (lower). To this day, in certain parts of the world flame safety lamps are still in service.
The modern era of gas detection started in 1926–1927 with the development of the catalytic combustion (LEL) sensor by Dr.Oliver Johnson. Dr Johnson was an employee of Standard Oil Company in California (now Chevron), he began research and development on a method to detect combustible mixtures in air to help prevent explosions in fuel storage tanks. A demonstration model was developed in 1926 and denoted as the Model A. The first practical "electric vapor indicator" meter begun production in 1927 with the release of the Model B.
The world's first gas detection company, Johnson-Williams Instruments (or J-W Instruments) was formed in 1928 in Palo Alto, CA by Dr Oliver Johnson and Phil Williams. J-W Instruments is recognized as the first electronics company in Silicon Valley. Over the next 40 years J-W Instruments pioneered many "firsts" in the modern age of gas detection, including making instruments smaller and more portable, development of a portable oxygen detector as well as the first combination instrument that could detect both combustible gases/vapors as well as oxygen.
Before the development of electronic household carbon monoxide detectors in the 1980s and 1990s, carbon monoxide presence was detected with a chemically infused paper that turned brown when exposed to the gas. Since then, many electronic technologies and devices have been developed to detect, monitor, and alert the leak of a wide array of gases.
As the cost and performance of electronic gas sensors improved, they have been incorporated into a wider range of systems. Their use in automobiles was initially for engine emissions control, but now gas sensors may also be used to ensure passenger comfort and safety. Carbon dioxide sensors are being installed into buildings as part of demand-controlled ventilation systems. Sophisticated gas sensor systems are being researched for use in medical diagnostic, monitoring, and treatment systems, well beyond their initial use in operating rooms. Gas monitors and alarms for carbon monoxide and other harmful gases are increasingly available for office and domestic use, and are becoming legally required in some jurisdictions.
Originally, detectors were produced to detect a single gas. Modern units may detect several toxic or combustible gases, or even a combination. Newer gas analyzers can break up the component signals from a complex aroma to identify several gases simultaneously.
Metal–oxide–semiconductor (MOS) sensors were introduced in the 1990s. The earliest known MOS gas sensor was demonstrated by G. Sberveglieri, G. Faglia, S. Groppelli, P. Nelli and A. Camanzi in 1990. MOS sensors have since become important environmental gas detectors.
Types Gas detectors can be classified according to the operation mechanism (semiconductor, oxidation, catalytic, photoionization, infrared, etc.). Gas detectors come packaged into two main form factors: portable devices and fixed gas detectors.
Portable detectors are used to monitor the atmosphere around personnel and are either hand-held or worn on clothing or on a belt/harness. These gas detectors are usually battery operated. They transmit warnings via audible and visible signals, such as alarms and flashing lights, when dangerous levels of gas vapors are detected.
Fixed type gas detectors may be used for detection of one or more gas types. Fixed type detectors are generally mounted near the process area of a plant or control room, or an area to be protected, such as a residential bedroom. Generally, industrial sensors are installed on fixed type mild steel structures and a cable connects the detectors to a supervisory control and data acquisition (SCADA) system for continuous monitoring. A tripping interlock can be activated for an emergency situation.
Electrochemical
Electrochemical gas detectors work by allowing gases to diffuse through a porous membrane to an electrode where it is either chemically oxidized or reduced. The amount of current produced is determined by how much of the gas is oxidized at the electrode,Detcon, http://www.detcon.com/electrochemical01.htm indicating the concentration of the gas. Manufactures can customize electrochemical gas detectors by changing the porous barrier to allow for the detection of a certain gas concentration range. Also, since the diffusion barrier is a physical/mechanical barrier, the detectors tend to be more stable and reliable over the sensor's duration and thus required less maintenance than other early detector technologies.
However, the sensors are subject to corrosive elements or chemical contamination and may last only 1–2 years before a replacement is required.United States Patent 4141800: Electrochemical gas detector and method of using same, http://www.freepatentsonline.com/4141800.html Electrochemical gas detectors are used in a wide variety of environments such as refineries, gas turbines, chemical plants, underground gas storage facilities, and more.
Catalytic bead Catalytic bead (pellistor) sensors are commonly used to measure combustible gases that present an explosion hazard when concentrations are between the lower explosion limit (LEL) and upper explosion limit (UEL). Active and reference beads containing platinum wire coils are situated on opposite arms of a Wheatstone bridge circuit and electrically heated, up to a few hundred degrees C. The active bead contains a catalyst that allows combustible compounds to oxidize, thereby heating the bead even further and changing its electrical resistance. The resulting voltage difference between the active and passive beads is proportional to the concentration of all combustible gases and vapors present. The sampled gas enters the sensor through a sintered metal frit, which provides a barrier to prevent an explosion when the instrument is carried into an atmosphere containing combustible gases. Pellistors measure essentially all combustible gases, but they are more sensitive to smaller molecules that diffuse through the sinter more quickly. The measurable concentration ranges are typically from a few hundred ppm to a few volume percent. Such sensors are inexpensive and robust, but require a minimum of a few percent oxygen in the atmosphere to be tested and they can be poisoned or inhibited by compounds such as silicones, mineral acids, chlorinated organic compounds, and sulfur compounds.
Photoionization
Photoionization detectors (PIDs) use a high-photon-energy UV lamp to ionize chemicals in the sampled gas. If the compound has an ionization energy below that of the lamp photons, an electron will be ejected, and the resulting current is proportional to the concentration of the compound. Common lamp photon energies include 10.0 eV, 10.6 eV and 11.7 eV; the standard 10.6 eV lamp lasts for years, while the 11.7 eV lamp typically last only a few months and is used only when no other option is available. A broad range of compounds can be detected at levels ranging from a few parts per billion (ppb) to several thousand parts per million (ppm). Detectable compound classes in order of decreasing sensitivity include: aromatics and alkyl iodides; olefins, sulfur compounds, amines, ketones, ethers, alkyl bromides and silicate esters; organic esters, alcohols, aldehydes and alkanes; hydrogen sulfide, ammonia, phosphine and organic acids. There is no response to standard components of air or to mineral acids. Major advantages of PIDs are their excellent sensitivity and simplicity of use; the main limitation is that measurements are not compound-specific. Recently PIDs with pre-filter tubes have been introduced that enhance the specificity for such compounds as benzene or butadiene. Fixed, hand-held and miniature clothing-clipped PIDs are widely used for industrial hygiene, hazmat, and environmental monitoring.
Infrared point
Infrared (IR) point sensors use radiation passing through a known volume of gas; energy from the sensor beam is absorbed at certain wavelengths, depending on the properties of the specific gas. For example, carbon monoxide absorbs wavelengths of about 4.2-4.5 μm.Muda, R., 2009 The energy in this wavelength is compared to a wavelength outside of the absorption range; the difference in energy between these two wavelengths is proportional to the concentration of gas present.
This type of sensor is advantageous because it does not have to be placed into the gas to detect it and can be used for remote sensing. Infrared point sensors can be used to detect hydrocarbonsInternational Society of Automation, http://www.isa.org/Template.cfm?Section=Communities&template=/TaggedPage/DetailDisplay.cfm&ContentID=23377 and other infrared active gases such as water vapor and carbon dioxide. IR sensors are commonly found in waste-water treatment facilities, refineries, gas turbines, chemical plants, and other facilities where flammable gases are present and the possibility of an explosion exists. The remote sensing capability allows large volumes of space to be monitored.